PL RU EN

Cable TRANSDATAFLEX

                                             
                                                                                                                                               You can download this catalog in PDF

                Application
   Twisted pair shielded cable for authentic data and signal transmission and for high mechanical and electrical requirements in drag chains
applications, in movable electrical facilities and in the field of robotic technology. Used both for installation in confined spaces, or in
the open air, and is also resistant to UV radiation (solar radiation).

                Special features

  • decoupling of electric circuits by twisted pairs
  • halogen-free, flame-retardant and low adhesion
  • largely resistant to grease, to oil,  coolant fluids and lubricants
  • space- and weight-saving
  • can be individually desingned for use at low temperatures

           Remarks
  • conform to RoHS
  • very long lifetime, optimal cost-value ratio
  • we are pleased to produce special versions, other dimensions,
    core and jacket colours on request.

           Structure & Specifications
  • Conductor material

bare copper strand

  • Conductor class

acc.to DIN VDE 0295 class 6 resp. IEC 60228 cl. 6

  • Core insulation

PELON (polyester)

  • Core identification

according to DIN 47100

  • Overall shield

copper braid tinned; coverage appr. 85 %

  • Outer sheath
PUR
for low temperatures - special silicone
  • Sheath colour

grey RAL 7001, orange RAL 2003

  • Printing 

yes

  • Rated voltage

250 V, no high - voltage purposes

  • Testing voltage

1500 V

  • Conductor resistance

at +20oC acc. to DIN VDE 0295 class 6 resp. IEC 60228 cl. 6

  • Insulation resistance

at +20oC ≥ 20 M Ω  x  km

  • Min. bending radius fixed

5 x d

  • Min, bending radius moved

7,5 x d

  • Operating temperature fixed min/max
-50oC / +90oC
special version -60oC/ +90oC
  • Operating temperature moved min/max
-40oC / +90oC
special version -50oC / +90oC
  • Burning behavior

according to VDE 0482-332-2-1 resp. DIN EN 603332-2-1, flame - retardant

  • Standard

according to DIN VDE 0207, 0250, 0293, 0295 and 0472 resp. IEC

 

View:
Cable TRANSDATAFLEX 4х2х1
  • dimension n x mm2    - 4x(2x1)
  • outer diameter mm     - 11,8
  • copper weigh kg/km   - 110
  • weight kg/km             - 220