PL RU EN

H05V-R, H07V-R - cables with rigid stranded conductor

View:
Cable H05V-R (300/500 V) - 1x0,5
  • dimension  n x mm2   - 1x0,5
  • thickness of insulation  mm  -0,6
  • outer diameter   mm  - 2,4
  • approximate weigh   kg/km   ~ 8
  • Max. resistance at 20ºС  Ω/km - 36,0
Cable H05V-R (300/500 V) - 1x0,75
  • dimension  n x mm2   - 1x0,75
  • thickness of insulation  mm  -0,6
  • outer diameter   mm  - 2,6
  • approximate weigh   kg/km   ~ 11
  • Max. resistance at 20ºС  Ω/km - 24,5
Cable H05V-R (300/500 V) - 1x1
  • dimension  n x mm2   - 1x1
  • thickness of insulation  mm  -0,6
  • outer diameter   mm  - 2,8
  • approximate weigh   kg/km   ~ 14
  • Max. resistance at 20ºС  Ω/km - 18,1
Cable H07V-R (450/750 V) - 1x1,5
  • dimension  n x mm2   - 1x1,5
  • thickness of insulation  mm  -0,7
  • outer diameter   mm  - 3,3
  • approximate weigh   kg/km   ~ 20
  • Max. resistance at 20ºС  Ω/km - 12,1
Cable H07V-R (450/750 V) - 1x2,5
  • dimension  n x mm2   - 1x2,5
  • thickness of insulation  mm  -0,8
  • outer diameter   mm  - 4,0
  • approximate weigh   kg/km   ~ 31
  • Max. resistance at 20ºС  Ω/km - 7,41
Cable H07V-R (450/750 V) - 1x4
  • dimension  n x mm2   - 1x4
  • thickness of insulation  mm  -0,8
  • outer diameter   mm  - 4,6
  • approximate weigh   kg/km   ~ 46
  • Max. resistance at 20ºС  Ω/km - 4,61
Cable H07V-R (450/750 V) - 1x6
  • dimension  n x mm2   - 1x6
  • thickness of insulation  mm  -0,8
  • outer diameter   mm  - 5,5
  • approximate weigh   kg/km   ~ 65
  • Max. resistance at 20ºС  Ω/km - 3,08
Cable H07V-R (450/750 V) - 1x10
  • dimension  n x mm2   - 1x10
  • thickness of insulation  mm  -1,0
  • outer diameter   mm  - 6,7
  • approximate weigh   kg/km   ~ 108
  • Max. resistance at 20ºС  Ω/km - 1,83
Cable H07V-R (450/750 V) - 1x16
  • dimension  n x mm2   - 1x16
  • thickness of insulation  mm  -1,0
  • outer diameter   mm  - 7,8
  • approximate weigh   kg/km   ~ 167
  • Max. resistance at 20ºС  Ω/km - 1,15
Cable H07V-R (450/750 V) - 1x25
  • dimension  n x mm2   - 1x25
  • thickness of insulation  mm  -1,2
  • outer diameter   mm  - 9,7
  • approximate weigh   kg/km   ~ 258
  • Max. resistance at 20ºС  Ω/km - 0,727
Cable H07V-R (450/750 V) - 1x35
  • dimension  n x mm2   - 1x35
  • thickness of insulation  mm  -1,2
  • outer diameter   mm  - 10,9
  • approximate weigh   kg/km   ~ 341
  • Max. resistance at 20ºС  Ω/km - 0,524
Cable H07V-R (450/750 V) - 1x50
  • dimension  n x mm2   - 1x50
  • thickness of insulation  mm  -1,4
  • outer diameter   mm  - 12,8
  • approximate weigh   kg/km   ~ 480
  • Max. resistance at 20ºС  Ω/km - 0,387
Cable H07V-R (450/750 V) - 1x70
  • dimension  n x mm2   - 1x70
  • thickness of insulation  mm  -1,4
  • outer diameter   mm  - 14,6
  • approximate weigh   kg/km   ~ 672
  • Max. resistance at 20ºС  Ω/km - 0,268
Cable H07V-R (450/750 V) - 1x95
  • dimension  n x mm2   - 1x95
  • thickness of insulation  mm  -1,6
  • outer diameter   mm  - 17,1
  • approximate weigh   kg/km   ~ 932
  • Max. resistance at 20ºС  Ω/km - 0,193
Cable H07V-R (450/750 V) - 1x120
  • dimension  n x mm2   - 1x120
  • thickness of insulation  mm  -1,6
  • outer diameter   mm  - 18,8
  • approximate weigh   kg/km   ~ 1157
  • Max. resistance at 20ºС  Ω/km - 0,153
Cable H07V-R (450/750 V) - 1x150
  • dimension  n x mm2   - 1x150
  • thickness of insulation  mm  -1,8
  • outer diameter   mm  - 20,9
  • approximate weigh   kg/km   ~ 1430
  • Max. resistance at 20ºС  Ω/km - 0,124
Cable H07V-R (450/750 V) - 1x185
  • dimension  n x mm2   - 1x185
  • thickness of insulation  mm  -2,0
  • outer diameter   mm  - 23,3
  • approximate weigh   kg/km   ~ 1790
  • Max. resistance at 20ºС  Ω/km - 0,0991
Cable H07V-R (450/750 V) - 1x240
  • dimension  n x mm2   - 1x240
  • thickness of insulation  mm  -2,2
  • outer diameter   mm  - 26,6
  • approximate weigh   kg/km   ~ 2325
  • Max. resistance at 20ºС  Ω/km - 0,0754
Cable H07V-R (450/750 V) - 1x300
  • dimension  n x mm2   - 1x300
  • thickness of insulation  mm  -2,4
  • outer diameter   mm  - 29,6
  • approximate weigh   kg/km   ~ 2905
  • Max. resistance at 20ºС  Ω/km - 0,0601
Cable H07V-R (450/750 V) - 1x400
  • dimension  n x mm2   - 1x400
  • thickness of insulation  mm  -2,6
  • outer diameter   mm  - 33б2
  • approximate weigh   kg/km   ~ 3755
  • Max. resistance at 20ºС  Ω/km - 0,0470