PL RU EN

Cable KYCFLY (flat)

                                            
                                                                                                                                               You can download this catalog in PDF

                Application
    Shielded power, control and signal transmission cable for crane facilities, current entries to high rack transport vehicles, in industrial
television on moving cameras and machine tools. Applicable for all control, measure and telecommunication systems. Suitable for dry and
humid rooms.

                Special features

  • significant smaller bending radius compared to round cables
  • free from lacquer damaging substances and silicone (during production)
  • cold resistant types KYCFLY, KYFLCY

           Remarks
  • conform to RoHS
  • conform to 2006/95/EC-Guideline CE.
  • we are pleased to produce special versions, other dimensions, core and jacket colours on request.


                Structure & Specifications

  • Conductor material

bare copper strand 

  • Conductor class

acc. to DIN VDE 0295 class 5 resp. IEC 60228 cl. 5

  • Core insulation

PVC

  • Core identification

acc. to DIN 0293-308 up to 5 wires coloured, from 6 wires white black numerals with or without gn/ye

  • Standing

cores resp. bundles parallel side by side

  • shield

single core or bundle with copper braid or wrapped wire tinned; coverage ca. 80% - 90%

  • Outer sheath
PVC
  • Sheath colour

black, RAL 9005

  • Printing

yes

  • Rated voltage                             

0,5 mm² = 300 V;> 1,0 mm² = Uo/U 300/500 V

  • testing voltage

1,2 kV / 2 kV

  • current carrying capacity 

acc. to DIN VDE, see Technical Guideline

  • min. bending radius fixed

10 x d

  • min. bending radius moved

10 x d

  • operat. Temp. fixed min/max

-25 °C/-40 °C / +60 °C/+70 °C

  • operat. Temp, moved min/max

-25 °C/-30 °C / +60 °C/+70 °C

  • temp. at conuctor

+70 °C

  • burning behavior

self-extinguishing and flame retardant acc. to IEC 60332-1

  • standart

acc. to DIN VDE 0250

 

View:
Cable KYCFLY 4G1,5
  • dimension n x mm2            - 4G1,5
  • dimension (height x width)  - 5,5 X 18,2 - 6,3 X 19,6
  • copper weigh kg/km            - 114
  • weight kg/km                        - 210
Cable KYCFLY 8G1,5
  • dimension n x mm2            - 8G1,5
  • dimension (height x width)  - 5,5 X 34,0 - 6,3 X 37,0
  • copper weigh kg/km            - 220
  • weight kg/km                        - 400
Cable KYCFLY 12G1,5
  • dimension n x mm2            - 12G1,5
  • dimension (height x width)  - 5,5 X 50,0 - 6,3 X 52,5
  • copper weigh kg/km            - 335
  • weight kg/km                        - 610
Cable KYCFLY 4G2,5
  • dimension n x mm2            - 4G2,5
  • dimension (height x width)  - 6,8 X 20,7 - 7,4 X 22,0
  • copper weigh kg/km            - 168
  • weight kg/km                        - 270
Cable KYCFLY 4G6
  • dimension n x mm2            - 4G6
  • dimension (height x width)  - 9,0 X 29,0 - 9,8 X 31,2
  • copper weigh kg/km            - 325
  • weight kg/km                        - 520
Cable KYCFLY 4G10
  • dimension n x mm2            - 4G10
  • dimension (height x width)  - 11,0 X 36,5 - 11,8 X 37,5
  • copper weigh kg/km            - 522
  • weight kg/km                        - 840
Cable KYCFLY 4G16
  • dimension n x mm2            - 4G16
  • dimension (height x width)  - 12,5 X 40,5 - 14,0 X 46,0
  • copper weigh kg/km            - 784
  • weight kg/km                        - 1280
Cable KYCFLY 4G25
  • dimension n x mm2            - 4G25
  • dimension (height x width)  - 14,5 X 49,0 - 15,0 X 51,0
  • copper weigh kg/km            - 1163
  • weight kg/km                        - 1800
Cable KYCFLY 8х7G0,5
  • dimension n x mm2            - 8x7G0,5
  • dimension (height x width)  - 11,7 X 67,8 - 12,5 X 71,0
  • copper weigh kg/km            - 455
  • weight kg/km                        - 1180
Cable KYCFLY 4х4G1
  • dimension n x mm2            - 4x4G1
  • dimension (height x width)  - 10,8 X 34,5 - 11,5 X 35,5
  • copper weigh kg/km            - 315
  • weight kg/km                        - 625
Cable YCFLY 5x0,5
  • dimension n x mm2            - 5x0,5
  • dimension (height x width)  - 4,2 X 19,5 - 5,0 X 22,0
  • copper weigh kg/km            - 60
  • weight kg/km                        - 140
Cable YCFLY 7х4G0,5
  • dimension n x mm2            - 7x4G0,5
  • dimension (height x width)  - 9,8 X 46,5 - 10,3 X 50,0
  • copper weigh kg/km            - 222
  • weight kg/km                        - 745
Cable YCFLY 7х3х1
  • dimension n x mm2            - 7x3x1
  • dimension (height x width)  - 9,8 X 46,8 - 10,3 X 50,0
  • copper weigh kg/km            - 275